| """Saswell (Tuya whitelabel) 88teujp thermostat valve quirk.""" | |
| import logging | |
| from zigpy.profiles import zha | |
| import zigpy.types as t | |
| from zigpy.zcl import foundation | |
| from zigpy.zcl.clusters.general import ( | |
| AnalogOutput, | |
| Basic, | |
| Groups, | |
| Identify, | |
| Ota, | |
| Scenes, | |
| Time, | |
| ) | |
| from zigpy.zcl.clusters.hvac import Thermostat | |
| from zhaquirks import Bus, LocalDataCluster | |
| from zhaquirks.const import ( | |
| DEVICE_TYPE, | |
| ENDPOINTS, | |
| INPUT_CLUSTERS, | |
| MODELS_INFO, | |
| OUTPUT_CLUSTERS, | |
| PROFILE_ID, | |
| ) | |
| from zhaquirks.tuya import ( | |
| TuyaManufClusterAttributes, | |
| TuyaPowerConfigurationCluster, | |
| TuyaThermostat, | |
| TuyaThermostatCluster, | |
| ) | |
| _LOGGER = logging.getLogger(__name__) | |
| SASWELL_HEATING_SETPOINT_ATTR = 0x0267 | |
| SASWELL_STATE_ATTR = 0x0165 | |
| SASWELL_LOCAL_TEMP_ATTR = 0x0266 | |
| SASWELL_BATTERY_LOW_ATTR = 0x0569 | |
| SASWELL_SCHEDULE_ENABLE_ATTR = 0x016C | |
| SASWELL_TEMPERATURE_CALIBRATION_ATTR = 0x021B # temperature calibration in degrees | |
| CTRL_SEQ_OF_OPER_ATTR = 0x001B | |
| MIN_HEAT_SETPOINT_ATTR = 0x0015 | |
| MAX_HEAT_SETPOINT_ATTR = 0x0016 | |
| class ManufacturerThermostatCluster(TuyaManufClusterAttributes): | |
| """Tuya manufacturer specific cluster.""" | |
| class State(t.enum8): | |
| """State option.""" | |
| Off = 0x00 | |
| On = 0x01 | |
| class BatteryState(t.enum8): | |
| """Battery state option.""" | |
| Normal = 0x00 | |
| Low = 0x01 | |
| class ScheduleState(t.enum8): | |
| """Schedule state option.""" | |
| Disabled = 0x00 | |
| Enabled = 0x01 | |
| attributes = TuyaManufClusterAttributes.attributes.copy() | |
| attributes.update( | |
| { | |
| SASWELL_STATE_ATTR: ("state", State, True), | |
| SASWELL_HEATING_SETPOINT_ATTR: ("heating_setpoint", t.uint32_t, True), | |
| SASWELL_LOCAL_TEMP_ATTR: ("local_temperature", t.uint32_t, True), | |
| SASWELL_BATTERY_LOW_ATTR: ("battery_state", BatteryState, True), | |
| SASWELL_SCHEDULE_ENABLE_ATTR: ("schedule_enabled", ScheduleState, True), | |
| SASWELL_TEMPERATURE_CALIBRATION_ATTR: ( | |
| "temperature_calibration", | |
| t.int32s, | |
| True, | |
| ), | |
| } | |
| ) | |
| TEMPERATURE_ATTRS = { | |
| SASWELL_HEATING_SETPOINT_ATTR: "occupied_heating_setpoint", | |
| SASWELL_LOCAL_TEMP_ATTR: "local_temperature", | |
| } | |
| async def write_attributes(self, attributes, manufacturer=None): | |
| """Overwrite to force manufacturer code.""" | |
| return await super().write_attributes( | |
| attributes, manufacturer=foundation.ZCLHeader.NO_MANUFACTURER_ID | |
| ) | |
| def _update_attribute(self, attrid, value): | |
| super()._update_attribute(attrid, value) | |
| if attrid in self.TEMPERATURE_ATTRS: | |
| self.endpoint.device.thermostat_bus.listener_event( | |
| "temperature_change", | |
| self.TEMPERATURE_ATTRS[attrid], | |
| value * 10, | |
| ) | |
| elif attrid == SASWELL_STATE_ATTR: | |
| self.endpoint.device.thermostat_bus.listener_event( | |
| "system_mode_reported", value | |
| ) | |
| elif attrid == SASWELL_BATTERY_LOW_ATTR: | |
| # this device doesn't have battery level reporting, only battery low alert | |
| # when the alert is active (1) we report 0% and 100% otherwise (0) | |
| self.endpoint.device.battery_bus.listener_event( | |
| "battery_change", 0 if value == 1 else 100 | |
| ) | |
| elif attrid == (SASWELL_TEMPERATURE_CALIBRATION_ATTR): | |
| self.endpoint.device.temperature_calibration_bus.listener_event( | |
| "set_value", value | |
| ) | |
| class ThermostatCluster(TuyaThermostatCluster): | |
| """Thermostat cluster.""" | |
| _CONSTANT_ATTRIBUTES = { | |
| MIN_HEAT_SETPOINT_ATTR: 500, | |
| MAX_HEAT_SETPOINT_ATTR: 3000, | |
| CTRL_SEQ_OF_OPER_ATTR: Thermostat.ControlSequenceOfOperation.Heating_Only, # the device supports heating mode | |
| } | |
| def system_mode_reported(self, value): | |
| """Handle reported system mode.""" | |
| if value == 1: | |
| self._update_attribute( | |
| self.attributes_by_name["system_mode"].id, Thermostat.SystemMode.Heat | |
| ) | |
| self._update_attribute( | |
| self.attributes_by_name["running_mode"].id, Thermostat.RunningMode.Heat | |
| ) | |
| _LOGGER.debug("reported system_mode: heat") | |
| else: | |
| self._update_attribute( | |
| self.attributes_by_name["system_mode"].id, Thermostat.SystemMode.Off | |
| ) | |
| self._update_attribute( | |
| self.attributes_by_name["running_mode"].id, Thermostat.RunningMode.Off | |
| ) | |
| _LOGGER.debug("reported system_mode: off") | |
| def map_attribute(self, attribute, value): | |
| """Map standardized attribute value to dict of manufacturer values.""" | |
| if attribute == "occupied_heating_setpoint": | |
| # centidegree to decidegree | |
| return {SASWELL_HEATING_SETPOINT_ATTR: round(value / 10)} | |
| if attribute == "system_mode": | |
| # this quirk does not support programmig modes so we force the schedule mode to be always off | |
| # more details: https://github.com/zigpy/zha-device-handlers/issues/1815 | |
| if value == self.SystemMode.Off: | |
| return {SASWELL_STATE_ATTR: 0, SASWELL_SCHEDULE_ENABLE_ATTR: 0} | |
| if value == self.SystemMode.Heat: | |
| return {SASWELL_STATE_ATTR: 1, SASWELL_SCHEDULE_ENABLE_ATTR: 0} | |
| class TuyaTemperatureOffset(LocalDataCluster, AnalogOutput): | |
| """AnalogOutput cluster for setting temperature offset.""" | |
| def __init__(self, *args, **kwargs): | |
| """Init.""" | |
| super().__init__(*args, **kwargs) | |
| self.endpoint.device.temperature_calibration_bus.add_listener(self) | |
| self._update_attribute( | |
| self.attributes_by_name["description"].id, "Temperature Offset" | |
| ) | |
| self._update_attribute(self.attributes_by_name["max_present_value"].id, 6) | |
| self._update_attribute(self.attributes_by_name["min_present_value"].id, -6) | |
| self._update_attribute(self.attributes_by_name["resolution"].id, 1) | |
| self._update_attribute(self.attributes_by_name["application_type"].id, 0x0009) | |
| self._update_attribute(self.attributes_by_name["engineering_units"].id, 62) | |
| def set_value(self, value): | |
| """Set new temperature offset value.""" | |
| self._update_attribute(self.attributes_by_name["present_value"].id, value) | |
| def get_value(self): | |
| """Get current temperature offset value.""" | |
| return self._attr_cache.get(self.attributes_by_name["present_value"].id) | |
| async def write_attributes(self, attributes, manufacturer=None): | |
| """Modify value before passing it to the set_data tuya command.""" | |
| for attrid, value in attributes.items(): | |
| if isinstance(attrid, str): | |
| attrid = self.attributes_by_name[attrid].id | |
| if attrid not in self.attributes: | |
| self.error("%d is not a valid attribute id", attrid) | |
| continue | |
| self._update_attribute(attrid, value) | |
| if attrid == 0x0055: # `present_value` | |
| await self.endpoint.tuya_manufacturer.write_attributes( | |
| {SASWELL_TEMPERATURE_CALIBRATION_ATTR: value}, manufacturer=None | |
| ) | |
| return ([foundation.WriteAttributesStatusRecord(foundation.Status.SUCCESS)],) | |
| class Thermostat_TYST11_c88teujp(TuyaThermostat): | |
| """Saswell 88teujp thermostat valve.""" | |
| def __init__(self, *args, **kwargs): | |
| """Init device.""" | |
| self.temperature_calibration_bus = Bus() | |
| super().__init__(*args, **kwargs) | |
| signature = { | |
| MODELS_INFO: [ | |
| ("_TYST11_KGbxAXL2", "GbxAXL2"), | |
| ("_TYST11_c88teujp", "88teujp"), | |
| ("_TYST11_azqp6ssj", "zqp6ssj"), | |
| ("_TYST11_yw7cahqs", "w7cahqs"), | |
| ("_TYST11_9gvruqf5", "gvruqf5"), | |
| ("_TYST11_zuhszj9s", "uhszj9s"), | |
| ("_TYST11_caj4jz0i", "aj4jz0i"), | |
| ], | |
| ENDPOINTS: { | |
| # <SimpleDescriptor endpoint=1 profile=260 device_type=0 | |
| # device_version=0 | |
| # input_clusters=[0, 3] | |
| # output_clusters=[3, 25]> | |
| 1: { | |
| PROFILE_ID: zha.PROFILE_ID, | |
| DEVICE_TYPE: zha.DeviceType.ON_OFF_SWITCH, | |
| INPUT_CLUSTERS: [ | |
| Basic.cluster_id, | |
| Identify.cluster_id, | |
| ], | |
| OUTPUT_CLUSTERS: [ | |
| Identify.cluster_id, | |
| Ota.cluster_id, | |
| ], | |
| } | |
| }, | |
| } | |
| replacement = { | |
| ENDPOINTS: { | |
| 1: { | |
| PROFILE_ID: zha.PROFILE_ID, | |
| DEVICE_TYPE: zha.DeviceType.THERMOSTAT, | |
| INPUT_CLUSTERS: [ | |
| Basic.cluster_id, | |
| TuyaPowerConfigurationCluster, | |
| Identify.cluster_id, | |
| ThermostatCluster, | |
| ManufacturerThermostatCluster, | |
| TuyaTemperatureOffset, | |
| ], | |
| OUTPUT_CLUSTERS: [ | |
| Identify.cluster_id, | |
| Ota.cluster_id, | |
| ], | |
| } | |
| }, | |
| } | |
| class Thermostat_TZE200_c88teujp(TuyaThermostat): | |
| """Saswell 88teujp thermostat valve.""" | |
| def __init__(self, *args, **kwargs): | |
| """Init device.""" | |
| self.temperature_calibration_bus = Bus() | |
| super().__init__(*args, **kwargs) | |
| signature = { | |
| MODELS_INFO: [ | |
| ("_TZE200_c88teujp", "TS0601"), | |
| ("_TZE200_azqp6ssj", "TS0601"), | |
| ("_TZE200_yw7cahqs", "TS0601"), | |
| ("_TZE200_9gvruqf5", "TS0601"), | |
| ("_TZE200_zuhszj9s", "TS0601"), | |
| ("_TZE200_zr9c0day", "TS0601"), | |
| ("_TZE200_0dvm9mva", "TS0601"), | |
| ("_TZE200_h4cgnbzg", "TS0601"), | |
| ("_TZE200_exfrnlow", "TS0601"), | |
| ("_TZE200_9m4kmbfu", "TS0601"), | |
| ("_TZE200_3yp57tby", "TS0601"), | |
| ], | |
| ENDPOINTS: { | |
| # <SimpleDescriptor endpoint=1 profile=260 device_type=81 | |
| # device_version=0 | |
| # input_clusters=[0, 4, 5, 61184] | |
| # output_clusters=[10, 25]> | |
| 1: { | |
| PROFILE_ID: zha.PROFILE_ID, | |
| DEVICE_TYPE: zha.DeviceType.SMART_PLUG, | |
| INPUT_CLUSTERS: [ | |
| Basic.cluster_id, | |
| Groups.cluster_id, | |
| Scenes.cluster_id, | |
| TuyaManufClusterAttributes.cluster_id, | |
| ], | |
| OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id], | |
| } | |
| }, | |
| } | |
| replacement = { | |
| ENDPOINTS: { | |
| 1: { | |
| PROFILE_ID: zha.PROFILE_ID, | |
| DEVICE_TYPE: zha.DeviceType.THERMOSTAT, | |
| INPUT_CLUSTERS: [ | |
| Basic.cluster_id, | |
| TuyaPowerConfigurationCluster, | |
| Groups.cluster_id, | |
| Scenes.cluster_id, | |
| ThermostatCluster, | |
| ManufacturerThermostatCluster, | |
| TuyaTemperatureOffset, | |
| ], | |
| OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id], | |
| } | |
| } | |
| } |