Solinteg hybrid inverter Home Assistant integration
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| modbus: | |
| - name: solinteg | |
| type: rtuovertcp | |
| host: 192.168.1.200 # YOUR INVERTER FIXED IP HERE | |
| port: 5743 | |
| delay: 0 | |
| message_wait_milliseconds: 30 | |
| timeout: 5 | |
| sensors: | |
| - name: Solinteg Inverter SN | |
| unique_id: solinteg_inverter_sn | |
| slave: 252 | |
| address: 10000 | |
| input_type: holding | |
| count: 10 | |
| data_type: string | |
| scan_interval: 86400 | |
| - name: Solinteg Inverter Running Status #0:wait, wait for on-grid 1:check, self-check 2:On Grid 3:fault 4:flash, firmware update 5.Off Grid | |
| unique_id: solinteg_inverter_running_status | |
| slave: 252 | |
| address: 10105 | |
| input_type: holding | |
| data_type: int16 | |
| scan_interval: 10 | |
| - name: Solinteg Phase A Power on Meter | |
| unique_id: solinteg_phase_a_power_on_meter | |
| slave: 252 | |
| address: 10994 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: kW | |
| device_class: power | |
| scale: 0.001 | |
| precision: 3 | |
| data_type: int32 | |
| scan_interval: 60 | |
| - name: Solinteg Phase B Power on Meter | |
| unique_id: solinteg_phase_b_power_on_meter | |
| slave: 252 | |
| address: 10996 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: kW | |
| device_class: power | |
| scale: 0.001 | |
| precision: 3 | |
| data_type: int32 | |
| scan_interval: 60 | |
| - name: Solinteg Phase C Power on Meter | |
| unique_id: solinteg_phase_c_power_on_meter | |
| slave: 252 | |
| address: 10998 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: kW | |
| device_class: power | |
| scale: 0.001 | |
| precision: 3 | |
| data_type: int32 | |
| scan_interval: 60 | |
| - name: Solinteg Total Power on Meter #Grid power | |
| unique_id: solinteg_total_power_on_meter | |
| slave: 252 | |
| address: 11000 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: kW | |
| device_class: power | |
| scale: 0.001 | |
| precision: 3 | |
| data_type: int32 | |
| scan_interval: 10 | |
| - name: Solinteg Grid Injection Energy on that day | |
| unique_id: solinteg_grid_injection_energy_on_that_day | |
| slave: 252 | |
| address: 31000 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing #measurement | |
| device_class: energy | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg Grid Purchasing Energy on that day | |
| unique_id: solinteg_grid_purchasing_energy_on_that_day | |
| slave: 252 | |
| address: 31001 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing #measurement | |
| device_class: energy | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg Backup Output Energy on that day | |
| unique_id: solinteg_backup_output_energy_on_that_day | |
| slave: 252 | |
| address: 31002 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing #measurement | |
| device_class: energy | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg Battery Charge Energy on that day | |
| unique_id: solinteg_battery_charge_energy_on_that_day | |
| slave: 252 | |
| address: 31003 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing #measurement | |
| device_class: energy | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg Battery Discharge Energy on that day | |
| unique_id: solinteg_battery_discharge_energy_on_that_day | |
| slave: 252 | |
| address: 31004 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing #measurement | |
| device_class: energy | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg PV Generation Energy on that day #E-today from GUI | |
| unique_id: solinteg_pv_generation_energy_on_that_day | |
| slave: 252 | |
| address: 31005 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing #measurement | |
| device_class: energy | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg Loading Energy on that day | |
| unique_id: solinteg_loading_energy_on_that_day | |
| slave: 252 | |
| address: 31006 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing #measurement | |
| device_class: energy | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg Energy Purchased from Grid on that day | |
| unique_id: solinteg_energy_purchased_from_grid_on_that_day | |
| slave: 252 | |
| address: 31008 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing #measurement | |
| device_class: energy | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg Total Energy injected to grid | |
| unique_id: solinteg_total_energy_injected_to_grid | |
| slave: 252 | |
| address: 31102 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing | |
| device_class: energy | |
| data_type: int32 | |
| scan_interval: 600 | |
| - name: Solinteg Total Energy Purchased from Grid from Meter | |
| unique_id: solinteg_total_energy_purchased_from_grid_from_meter | |
| slave: 252 | |
| address: 31104 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing | |
| device_class: energy | |
| data_type: int32 | |
| scan_interval: 600 | |
| - name: Solinteg Total Output Energy on backup port | |
| unique_id: solinteg_total_output_energy_on_backup_port | |
| slave: 252 | |
| address: 31106 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing | |
| device_class: energy | |
| data_type: int32 | |
| scan_interval: 3600 | |
| - name: Solinteg Total Energy Charged to Battery | |
| unique_id: solinteg_total_energy_charged_to_battery | |
| slave: 252 | |
| address: 31108 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing | |
| device_class: energy | |
| data_type: int32 | |
| scan_interval: 600 | |
| - name: Solinteg Total Energy Discharged from Battery | |
| unique_id: solinteg_total_energy_discharged_from_battery | |
| slave: 252 | |
| address: 31110 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing | |
| device_class: energy | |
| data_type: int32 | |
| scan_interval: 600 | |
| - name: Solinteg Total PV Generation | |
| unique_id: solinteg_total_pv_generation | |
| slave: 252 | |
| address: 31112 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing | |
| device_class: energy | |
| data_type: int32 | |
| scan_interval: 600 | |
| - name: Solinteg Total Loading Energy consumed at grid side | |
| unique_id: solinteg_total_loading_energy_consumed_at_grid_side | |
| slave: 252 | |
| address: 31114 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing | |
| device_class: energy | |
| data_type: int32 | |
| scan_interval: 3600 | |
| - name: Solinteg Total Energy Purchased from Grid at inverter side | |
| unique_id: solinteg_total_energy_purchased_from_grid_at_inverter_side | |
| slave: 252 | |
| address: 31118 | |
| scale: 0.1 | |
| precision: 1 | |
| input_type: holding | |
| unit_of_measurement: kWh | |
| state_class: total_increasing | |
| device_class: energy | |
| data_type: int32 | |
| scan_interval: 3600 | |
| - name: Solinteg Total Grid-Injection Energy on Meter | |
| unique_id: solinteg_total_grid_injection_energy_on_meter | |
| slave: 252 | |
| address: 11002 | |
| input_type: holding | |
| state_class: total_increasing | |
| unit_of_measurement: kWh | |
| device_class: energy | |
| scale: 0.01 | |
| precision: 2 | |
| data_type: int32 | |
| scan_interval: 3600 | |
| - name: Solinteg Total Purchasing Energy from Grid on Meter | |
| unique_id: solinteg_total_purchasing_energy_from_grid_on_meter | |
| slave: 252 | |
| address: 11004 | |
| input_type: holding | |
| state_class: total_increasing | |
| unit_of_measurement: kWh | |
| device_class: energy | |
| scale: 0.01 | |
| precision: 2 | |
| data_type: int32 | |
| scan_interval: 3600 | |
| - name: Solinteg Grid Lines A/B Voltage | |
| unique_id: solinteg_grid_lines_a_b_voltage | |
| slave: 252 | |
| address: 11006 | |
| input_type: holding | |
| unit_of_measurement: V | |
| state_class: measurement | |
| device_class: voltage | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 60 | |
| - name: Solinteg Grid Lines B/C Voltage | |
| unique_id: solinteg_grid_lines_b_c_voltage | |
| slave: 252 | |
| address: 11007 | |
| input_type: holding | |
| unit_of_measurement: V | |
| state_class: measurement | |
| device_class: voltage | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 60 | |
| - name: Solinteg Grid Lines C/A Voltage | |
| unique_id: solinteg_grid_lines_c_a_voltage | |
| slave: 252 | |
| address: 11008 | |
| input_type: holding | |
| unit_of_measurement: V | |
| state_class: measurement | |
| device_class: voltage | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 60 | |
| - name: Solinteg Grid Phase A Voltage | |
| unique_id: solinteg_grid_phase_a_voltage | |
| slave: 252 | |
| address: 11009 | |
| input_type: holding | |
| unit_of_measurement: V | |
| state_class: measurement | |
| device_class: voltage | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 60 | |
| - name: Solinteg Grid Phase B Voltage | |
| unique_id: solinteg_grid_phase_b_voltage | |
| slave: 252 | |
| address: 11011 | |
| input_type: holding | |
| unit_of_measurement: V | |
| state_class: measurement | |
| device_class: voltage | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 60 | |
| - name: Solinteg Grid Phase C Voltage | |
| unique_id: solinteg_grid_pase_c_voltage | |
| slave: 252 | |
| address: 11013 | |
| input_type: holding | |
| unit_of_measurement: V | |
| state_class: measurement | |
| device_class: voltage | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 60 | |
| - name: Solinteg Grid Phase A Current | |
| unique_id: solinteg_grid_phase_a_current | |
| slave: 252 | |
| address: 11010 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: A | |
| device_class: current | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 60 | |
| - name: Solinteg Grid Phase B Current | |
| unique_id: solinteg_grid_phase_b_current | |
| slave: 252 | |
| address: 11012 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: A | |
| device_class: current | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 60 | |
| - name: Solinteg Grid Phase C Current | |
| unique_id: solinteg_grid_phase_c_current | |
| slave: 252 | |
| address: 11014 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: A | |
| device_class: current | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 60 | |
| - name: Solinteg P AC | |
| unique_id: solinteg_p_ac | |
| slave: 252 | |
| address: 11016 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: kW | |
| device_class: power | |
| scale: 0.001 | |
| precision: 3 | |
| data_type: int32 | |
| scan_interval: 10 | |
| - name: Solinteg Total PV Generation on that day | |
| unique_id: solinteg_total_pv_generation_on_that_day | |
| slave: 252 | |
| address: 11018 | |
| input_type: holding | |
| state_class: total_increasing #measurement | |
| device_class: energy | |
| unit_of_measurement: kWh | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int32 | |
| scan_interval: 1800 | |
| - name: Solinteg Total PV Generation from Installation | |
| unique_id: solinteg_total_pv_generation_from_installation | |
| slave: 252 | |
| address: 11020 | |
| input_type: holding | |
| state_class: total_increasing #measurement | |
| device_class: energy | |
| unit_of_measurement: kWh | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int32 | |
| scan_interval: 3600 | |
| - name: Solinteg PV Input Total Power #PV power, panel actual power | |
| unique_id: solinteg_pv_input_total_power | |
| slave: 252 | |
| address: 11028 | |
| input_type: holding | |
| state_class: measurement | |
| device_class: power | |
| unit_of_measurement: kW | |
| scale: 0.001 | |
| precision: 3 | |
| data_type: int32 | |
| scan_interval: 10 | |
| - name: Solinteg Temperature Sensor 1 | |
| unique_id: solinteg_temperature_sensor_1 | |
| slave: 252 | |
| address: 11032 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 600 | |
| - name: Solinteg Temperature Sensor 2 | |
| unique_id: solinteg_temperature_sensor_2 | |
| slave: 252 | |
| address: 11033 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 600 | |
| - name: Solinteg Temperature Sensor 3 | |
| unique_id: solinteg_temperature_sensor_3 | |
| slave: 252 | |
| address: 11034 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 600 | |
| - name: Solinteg Temperature Sensor 4 | |
| unique_id: solinteg_temperature_sensor_4 | |
| slave: 252 | |
| address: 11035 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 600 | |
| - name: Solinteg PV1 Voltage | |
| unique_id: solinteg_pv1_voltage | |
| slave: 252 | |
| address: 11038 | |
| input_type: holding | |
| unit_of_measurement: V | |
| state_class: measurement | |
| device_class: voltage | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg PV2 Voltage | |
| unique_id: solinteg_pv2_voltage | |
| slave: 252 | |
| address: 11040 | |
| input_type: holding | |
| unit_of_measurement: V | |
| state_class: measurement | |
| device_class: voltage | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg PV1 Current | |
| unique_id: solinteg_pv1_current | |
| slave: 252 | |
| address: 11039 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: A | |
| device_class: current | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg PV2 Current | |
| unique_id: solinteg_pv2_current | |
| slave: 252 | |
| address: 11041 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: A | |
| device_class: current | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg PV1 Input Power | |
| unique_id: solinteg_pv1_input_power | |
| slave: 252 | |
| address: 11062 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: kW | |
| device_class: power | |
| scale: 0.001 | |
| precision: 3 | |
| data_type: int32 | |
| scan_interval: 10 | |
| - name: Solinteg PV2 Input Power | |
| unique_id: solinteg_pv2_input_power | |
| slave: 252 | |
| address: 11064 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: kW | |
| device_class: power | |
| scale: 0.001 | |
| precision: 3 | |
| data_type: int32 | |
| scan_interval: 10 | |
| - name: Solinteg Total Backup P #load power | |
| unique_id: solinteg_total_backup_p | |
| slave: 252 | |
| address: 30230 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: kW | |
| device_class: power | |
| scale: 0.001 | |
| precision: 3 | |
| data_type: int32 | |
| scan_interval: 10 | |
| - name: Solinteg Battery V #DC Voltage | |
| unique_id: solinteg_battery_v | |
| slave: 252 | |
| address: 30254 | |
| input_type: holding | |
| unit_of_measurement: V | |
| state_class: measurement | |
| device_class: voltage | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg Battery I #DC Current | |
| unique_id: solinteg_battery_i | |
| slave: 252 | |
| address: 30255 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: A | |
| device_class: current | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg Battery P #Battery Power | |
| unique_id: solinteg_battery_p | |
| slave: 252 | |
| address: 30258 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: kW | |
| device_class: power | |
| scale: 0.001 | |
| precision: 3 | |
| data_type: int32 | |
| scan_interval: 10 | |
| - name: Solinteg Battery Mode #0:discharge;1:charge | |
| unique_id: solinteg_battery_mode | |
| slave: 252 | |
| address: 30256 | |
| input_type: holding | |
| data_type: int16 | |
| scan_interval: 10 | |
| - name: Solinteg BMS Pack Temperature | |
| unique_id: solinteg_bms_pack_temperature | |
| slave: 252 | |
| address: 33003 | |
| input_type: holding | |
| state_class: measurement | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| scale: 0.1 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 300 | |
| - name: Solinteg Battery SOC | |
| unique_id: solinteg_battery_soc | |
| slave: 252 | |
| address: 33000 | |
| input_type: holding | |
| state_class: measurement | |
| #unit_of_measurement: '%' | |
| device_class: battery | |
| scale: 0.01 | |
| precision: 2 | |
| data_type: int16 | |
| scan_interval: 60 | |
| - name: Solinteg Battery SOH | |
| unique_id: solinteg_battery_soh | |
| slave: 252 | |
| address: 33001 | |
| input_type: holding | |
| state_class: measurement | |
| #unit_of_measurement: '%' | |
| device_class: battery | |
| scale: 0.01 | |
| precision: 2 | |
| data_type: int16 | |
| scan_interval: 3600 | |
| #RW values | |
| - name: Solinteg Hybrid Inverter Working Mode Setting #257=General mode; 258=Economic mode; 259=UPS mode; asi 512=Off grid mode | |
| unique_id: solinteg_hybrid_inverter_working_mode_setting #RW | |
| slave: 252 | |
| address: 50000 | |
| input_type: holding | |
| data_type: int16 | |
| scan_interval: 60 | |
| - name: Solinteg Grid Injection Power Limit Switch #0:Off;1:ON | |
| unique_id: solinteg_grid_injection_power_limit_switch #RW | |
| slave: 252 | |
| address: 25100 | |
| input_type: holding | |
| data_type: int16 | |
| scan_interval: 360 | |
| - name: Solinteg Grid Injection Power Limit Setting #[0.0%-100.0%] | |
| unique_id: solinteg_grid_injection_power_limit_setting #RW | |
| slave: 252 | |
| address: 25103 | |
| input_type: holding | |
| scale: 0.1 #spec: 1000 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 360 | |
| - name: Solinteg Priority Power Output Setting #0:PV Output Priority ; 1:Battery Output Priority | |
| unique_id: solinteg_priority_power_output_setting #RW | |
| slave: 252 | |
| address: 50210 | |
| input_type: holding | |
| data_type: int16 | |
| scan_interval: 360 | |
| - name: Solinteg On-grid Battery End SOC #[0.0%-100.0%] | |
| unique_id: solinteg_on_grid_battery_end_soc #RW | |
| slave: 252 | |
| address: 52503 | |
| input_type: holding | |
| scale: 0.1 #spec: 1000 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 360 | |
| - name: Solinteg Off-grid Battery End SOC #[0.0%-100.0%] | |
| unique_id: solinteg_off_grid_battery_end_soc #RW | |
| slave: 252 | |
| address: 52505 | |
| input_type: holding | |
| scale: 0.1 #spec: 1000 | |
| precision: 1 | |
| data_type: int16 | |
| scan_interval: 360 | |
| - name: Solinteg On-grid Battery SOC Protection Switch #0:Off;1:ON | |
| unique_id: solinteg_on_grid_battery_soc_protection_switch #RW | |
| slave: 252 | |
| address: 52502 | |
| input_type: holding | |
| data_type: int16 | |
| scan_interval: 360 | |
| - name: Solinteg Off-grid Battery SOC Protection Switch #0:Off;1:ON | |
| unique_id: solinteg_off_grid_battery_soc_protection_switch #RW | |
| slave: 252 | |
| address: 52504 | |
| input_type: holding | |
| data_type: int16 | |
| scan_interval: 360 | |
| sensor: | |
| - platform: template | |
| sensors: | |
| solinteg_battery_mode_text: | |
| friendly_name: Solinteg Battery Mode | |
| value_template: > | |
| {% if states('sensor.solinteg_battery_mode') == '0' %} | |
| discharge | |
| {% else %} | |
| charge | |
| {% endif %} | |
| solinteg_hybrid_inverter_working_mode_setting_text: | |
| friendly_name: Solinteg Hybrid Inverter Working Mode | |
| value_template: > | |
| {% if states('sensor.solinteg_hybrid_inverter_working_mode_setting') == '257' %} | |
| General mode | |
| {% elif states('sensor.solinteg_hybrid_inverter_working_mode_setting') == '258' %} | |
| Economic mode | |
| {% elif states('sensor.solinteg_hybrid_inverter_working_mode_setting') == '259' %} | |
| UPS mode | |
| {% elif states('sensor.solinteg_hybrid_inverter_working_mode_setting') == '512' %} | |
| Offgrid mode | |
| {% endif %} | |
| solinteg_inverter_running_status_text: | |
| friendly_name: Solinteg Inverter Running Status | |
| value_template: > | |
| {% if states('sensor.solinteg_inverter_running_status') == '0' %} | |
| wait | |
| {% elif states('sensor.solinteg_inverter_running_status') == '1' %} | |
| check | |
| {% elif states('sensor.solinteg_inverter_running_status') == '2' %} | |
| On Grid | |
| {% elif states('sensor.solinteg_inverter_running_status') == '3' %} | |
| fault | |
| {% elif states('sensor.solinteg_inverter_running_status') == '4' %} | |
| flash | |
| {% elif states('sensor.solinteg_inverter_running_status') == '5' %} | |
| Off Grid | |
| {% endif %} |
Author
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Out of the box configuration for Solinteg hybrid inverters. Works with the basic Solinteg Wi-Fi module.
Original source: https://github.com/GiZMoSK1221/hass-addons/tree/main/wattsonic
Special thanks to Attilla Keller:
https://www.facebook.com/groups/HomeAssistant/posts/3872367566367918/